PRV'S, when specified for each pump are pilot operated angle type to provide constant down-stream pressure and to minimize losses. Valve location and construction allows ease in servicing. PRV's are combination type and include non-slam check valves. Single System
PRV's in both pilot operated and direct acting styles are available.
Non-Slam Check Valves are used for each pump when PRV's are not used.
Manifolds are all 300 series Stainless Steel to insure compatibility with pumpage, rigid
construction, and use for potable water systems. Non corrosive nature of manifolds allows broad application, eliminates use of non-recommended lead sweats or other potentially toxic materials; also eliminating any requirement for dielectric fittings associated with galvanized pipe.
Base plate is solid steel to provide maximum support and strength.
Suction and Discharge Pressure Gauges are standard and allow system monitoring.
Control Panel is UL listed, contains magnetic starters, thermal overload relays, circuit breakers, disconnect for each pump, externally resettable H-O-A switches, motor run lights, 120 VAC control transformers. Panel is complete with programmable alarm functions (which can all be varied by time of day, season, jobsite conditions, etc.). Features include Lead Pump failure protection, 24 hour alternation of equal sized pumps, variable time sequencing, high suction pressure shutdown, low suction pressure/level shutdown, no flow shutdown, high system pressure shutdown, with individual lights for each condition as well as audible alarm and reset. Panel options are virtually unlimited and include visual LED read-out, phase-loss, lighting arrestors, etc.
Hydropneumatic Tanks are ASME code, FDA approved bladder type with full draw down and are available in a variety of sizes and ratings. Tanks are either system or remote mounted and provide maximum energy conservation and flexibility.
Pressure Transducers rather than pressure switches are used to sense pressure changes for maximum accuracy.
Flow Sequencing using the Pacomonitor direct acting flow sensor insures highest accuracy and maximum savings. Standard duplex sequencing is 3 step, while triplex sequencing is 5 step, eliminating wasted power consumption and most closely matching the individual pumps to the demand. No-flow shutdown adds another step to these already advanced sequencing functions. Pressure sensing or current sensing sequencing is also available when required.
Thermal Purge system is standard and allows purging of hot water when continued operation at no flow creates excessive heat, in order to protect the pumps. |